Skip to product information
1 of 4

Fire By Design

Rectangle Drop In Burner Pan Kit - T Burner - 24V

Rectangle Drop In Burner Pan Kit - T Burner - 24V

Regular price $2,950.99
Regular price $3,541.99 Sale price $2,950.99
Sale Sold out
Shipping calculated at checkout.

24" x 12" Rectangle Hybrid Drop In Burner Pan with Opening for Pilot Burner (26" x 14" OD)

  • 12" Single Linear Burner - 17K BTU's (316 Stainless Steel)
  • 1/2 Gas Inlet with NG Orifice or LP Air Mixer
  • AWEIS Standard Capacity with a Field Serviceable Pilot Burner
  • Natural Gas or Liquid Propane
  • Liquid Propane Includes 24V Safety Backup Valve
  • Includes 24V Transformer; (1) 18" Whisper Free Flex Gas Line 1/2"
  • Note: Holds 25lbs of Fire Glass / 2 Bags of Lava Rock / 1 Bag of Rolled Lava Stone 

36" x 12" Rectangle Hybrid Drop In Burner Pan with Opening for Pilot Burner (38" x 14" OD)

  • 24" Single Linear Burner - 34K BTU's (316 Stainless Steel)
  • 1/2 Gas Inlet with NG Orifice or LP Air Mixer
  • AWEIS Standard Capacity with a Field Serviceable Pilot Burner
  • Natural Gas or Liquid Propane
  • Liquid Propane Includes 24V Safety Backup Valve
  • Includes 24V Transformer; (1) 18" Whisper Free Flex Gas Line 1/2"
  • Note: Holds 38lbs of Fire Glass / 2 Bags of Lava Rock / 1 Bag of Rolled Lava Stone

48" x 12" Rectangle Hybrid Drop In Burner Pan with Opening for Pilot Burner (50" x 14" OD)

  • 36" Single Linear Burner - 51K BTU's (316 Stainless Steel)
  • 1/2 Gas Inlet with NG Orifice or LP Air Mixer
  • AWEIS Standard Capacity with a Field Serviceable Pilot Burner
  • Natural Gas or Liquid Propane
  • Liquid Propane Includes 24V Safety Backup Valve
  • Includes 24V Transformer; (1) 18" Whisper Free Flex Gas Line 1/2"
  • Note: Holds 51lbs of Fire Glass / 3 Bags of Lava Rock / 1 Bag of Rolled Lava Stone 

60" x 12" Rectangle Hybrid Drop In Burner Pan with Opening for Pilot Burner (62" x 14" OD)

  • 48" Single Linear Burner - 68K BTU's (316 Stainless Steel)
  • 1/2 Gas Inlet with NG Orifice or LP Air Mixer
  • AWEIS Standard Capacity with a Field Serviceable Pilot Burner
  • Natural Gas or Liquid Propane
  • Liquid Propane Includes 24V Safety Backup Valve
  • Includes 24V Transformer; (1) 18" Whisper Free Flex Gas Line 1/2"
  • Note: Holds 63lbs of Fire Glass / 4 Bags of Lava Rock / 1 Bags of Rolled Lava Stone

72" x 12" Rectangle Hybrid Drop In Burner Pan with Opening for Pilot Burner (74" x 14" OD)

  • 60" Single Linear Burner - 85K BTU's (316 Stainless Steel)
  • 1/2 Gas Inlet with NG Orifice or LP Air Mixer
  • AWEIS Standard Capacity with a Field Serviceable Pilot Burner
  • Natural Gas or Liquid Propane
  • Liquid Propane Includes 24V Safety Backup Valve
  • Includes 24V Transformer; (1) 18" Whisper Free Flex Gas Line 1/2"
  • Note: Holds 76lbs of Fire Glass / 4 Bags of Lava Rock / 2 Bags of Rolled Lava Stone

84" x 12" Rectangle Hybrid Drop In Burner Pan with Opening for Pilot Burner (86" x 14" OD)

  • 72" Single Linear Burner - 102K BTU's (316 Stainless Steel)
  • 1/2 Gas Inlet with NG Orifice or LP Air Mixer
  • AWEIS Standard Capacity with a Field Serviceable Pilot Burner
  • Natural Gas or Liquid Propane
  • Liquid Propane Includes 24V Safety Backup Valve
  • Includes 24V Transformer; (1) 18" Whisper Free Flex Gas Line 1/2"
  • Note: Holds 89lbs of Fire Glass / 5 Bags of Lava Rock / 2 Bags of Rolled Lava Stone

96" x 12" Rectangle Hybrid Drop In Burner Pan with Opening for Pilot Burner (98" x 14" OD)

  • 84" Single Linear Burner - 119K BTU's (316 Stainless Steel)
  • 1/2 Gas Inlet with NG Orifice or LP Air Mixer
  • AWEIS Standard Capacity with a Field Serviceable Pilot Burner
  • Natural Gas or Liquid Propane
  • Liquid Propane Includes 24V Safety Backup Valve
  • Includes 24V Transformer; (1) 18" Whisper Free Flex Gas Line 1/2"
  • Note: Holds 102lbs of Fire Glass / 6 Bags of Lava Rock / 2 Bags of Rolled Lava Stone 

*** Burner Pan Note: Drop In Burner Pans have a depth of 2.5" and have a 1" Flange all the way around (unless specified as a different size by customer) to support itself inside the opening it is installed in. Opening Size should be no more than 1" larger than Pan Dimensions ***

 

Documents

Preinstallation Checklist

Spec Sheet for Low Profile Standard Capacity

Spec Sheet for High Profile Standard Capacity

Spec Sheet for Low Profile High Capacity

Spec Sheet for High Profile High Capacity

Pilot Burner Assembly Differences

AWEIS Troubleshooting Guide

AWEIS Installation Instructions

Automated Fire 101

Flat Pan And Burner Instructions

Drop In Pan And Burner Instructions

Flat Burner Pan Support Structure

Burner Pan Joiner Plate Instructions

View full details